B-1020


COAXIAL CABLE DRIVER & MATCHING AMPLIFIERS


 coaxial

FIBER OPTIC TRANSMISSION ALSO AVAILABLE

  • Wideband: DC to over 30MHz
  • Maximum Output: to 10V PK, 20V PK-PK
  • Maximum Input: ±5V to ±200V PK-PK as required. Also to 900kV PK with Ross Voltage Divider
  • Signal Isolation: 500,000 Ohm 450V PK
  • Input Impedance: Up to 2 Megohms
  • Load Impedance: 50 Ohm or greater
  • Power Source: AC or Optional Battery
  • Will drive over 500 Feet of Coaxial Cable

Matching Amplifier
Model VDE-
Wideband: DC to over 30MHz

  • Signal Input
    • 0 to ±50 volt peak differential.
    • (0-100V PK-PK) standard. Other available.
    • Peak common mode voltage that will not damage amplifier or distort the output.
      • 200 volt steady state
      • 450 volt transient
    • Impedance
      • 1.0 megohm in parallel with 10pF or 2.0 meghom in parallel with 15pF as ordered. 
  • Signal Output
    • 0 to ±10 volts (20 volts PK-PK) into 50 ohm or greater load.
    • ±200mA. Peak Maximum load current.
    • Matching amplifier isolation of signal output from signal input is 500 kilohm in parallel with 20pF.
    • Gain / frequency. See figure #1 below
    • Undistorted output voltage swing. See figure #2 below
    • Square wave input. Rise and fall time<10ns.
    • Matching amplifier output is calibrated into a specified length of cable and a 50 ohm or greater load as specified by the customer.
  • Power Requirements
    • 105V to 125V AC, 50/60Hz.
    • Power Consumption-5W.
  • Environmental
    • Indoor.
    • 0 °C to +50 °C.
  • Dimensions
    • 3 1/2” high x 7” wide x 8 3/8” deep.
  • Miscellaneous
    • Red LED indicates power on.
    • Model VDE-Matching Amplifier includes cabinet, amplifier, 115 volt 50-400Hz power supply, cable and terminations as specified by the customer.
    • Power supply input isolated for 2000 volts.
    • Matching amplifier may also be used with other test equipment such as voltmeters, signal generators, recorders, etc.
  • WARNING
    • MATCHING AMPLIFIER OUTPUT COAXIAL CABLE SHIELD IS NOTGROUNDED. FOR SAFETY, OUTPUT COAXIAL CABLE SHIELD SHOULD BE GROUNDED AT COAXIAL CABLE TERMINATING RESISTOR.
    • If output coaxial cable is connected to matching amplifier input ground or matching amplifier 115 volt ground, there may be excessive ground currents causing electrical noise in matching amplifier output.
  • CAUTION
    • Do not subject output to reverse voltage.
    • External pickup from coaxial cables can easily exceed safe values if the cables are run near high pulse current conductors.
    • The matching amplifier, coaxial cable and coaxial cable terminating resistor are calibrated as a system.
    • If any of these are changed, the calibration, the high frequency response and the pulse response may change.
  • Options On Request
    • Signal Input Variations Available:
      • Any maximum input voltage from ±0.5 to over ±250 volt with proper input range selected, to over 900kV when using Ross Engineering Corp. voltage dividers.
    • Signal Output Variations Available:
      • Coaxial cable lengths from 0 to 500 feet
    • Power Options Available:
      • Battery or DC operated. 115V, 208V, 240V 50-400Hz.
    • Environment Additional Requirements Available:
      • Outdoor
      • Transformer Oil
    • Miscellaneous Available:
      • Power on/off switch

coaxial1


  Specifications are for reference only and are subject to change.
Contact Ross Engineering Corp. for current information.